2013 Volume 19 Issue 43 Pages 923-926
The author has proposed the formulas for estimating the confining ductility of R/C square columns. However, these formulas are not applicable to rectangular columns. In this paper, estimation method of the confining ductility of such columns is clarified on the basis of past tests result of wall specimens subjected to compressive force. Also, the required transverse reinforcement for ensuring the adequate ductility is shown.
Ethical standards of the publisher (‘Ethical Standards Concerning the Peer Review for the Presentation of Architectural Transactions and Works’)