AIJ Journal of Technology and Design
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
Environmental Engineering
DUST REDUCTION EFFECT OF AN ENCLOSED DEMOLITION METHOD OF A HIGH-RISE BUILDING
Taiki SATOKen SHOJIHideki ICHIHARAMasayuki OGURO
Author information
JOURNAL FREE ACCESS

2014 Volume 20 Issue 45 Pages 621-626

Details
Abstract
An enclosed demolition method of high-rise buildings is expected to reduce the dispersion amount of airborne particulate caused by demolition works. This paper describes ventilation performance and reduction effects of dust dispersion of this demolition method based on field measurements and numerical simulations. Our results showed that natural ventilation was promoted at openings that were designed in the border of the roof. Moreover, it was confirmed that 80 percent of the airborne particulate of the total dust produced by demolition works were deposited inside the enclosed space.
Content from these authors
© 2014 Architectural Institute of Japan
Previous article Next article
feedback