AIJ Journal of Technology and Design
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
Structures
EVALUATION OF THE FINE FRACTION CONTENT USING ELECTRICAL LOGGING METHOD
Yuanhao GAOMamoru FUJIIYasuhide MOCHIDAKotaro TAKECHIYukio ADACHI
Author information
JOURNAL FREE ACCESS

2015 Volume 21 Issue 48 Pages 557-562

Details
Abstract
SWS test is widely used as a research method to evaluate the residential sites. Advantage of SWS test is possible to evaluate the bearing capacity of residential sites. On the other hand, a disadvantage of SWS test is to determine soil and groundwater level. Suppose that if it is possible to incorporate the determination method of the soil by electrical resistivity using SWS test holes, a lot of information will be gained. As an ideal way, the electrical logging method by the electrode to the SWS test hole, is effective. Based on the above background, it was cleared that the evaluation of fine fraction content of soil was possible by electrical resistivity from the laboratory test. And the estimation equation was completed. In this study, field experiments of the six sites were performed to confirm the accuracy of the estimation equation from the laboratory test.
Content from these authors
© 2015 Architectural Institute of Japan
Previous article Next article
feedback
Top