In this study, the fireproof performance of high-density ALC floor panels was investigated. High-density ALC panels designed in accordance with the allowable stress under the design condition of 2,500mm less length, 3,500N/m2 less live load and 100mm more thickness have the fireproof performance which is necessary for Building Standards Act as a floor panel of fireproof construction. The fireproof performance of the floor structure using the high-density ALC panel can be evaluated by the parameters of the maximum load, the maximum length and the lowest thickness obtained by the fireproof test.