AIJ Journal of Technology and Design
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
Structures
STATIC LOADING TESTS FOR TIMBER FRAMES WITH LARGE HANGING WALLS USING DRY-MUD PANELS
Yoshihiro SHIBUYAYasuhiro NAMBUSaki OHMURATatsuya YOKOBEMina SUGINOYasuhiro HAYASHI
Author information
JOURNAL FREE ACCESS

2015 Volume 21 Issue 49 Pages 1031-1036

Details
Abstract

Static loading tests for timber frames with large hanging walls using dry-mud panels were conducted. Following results were obtained. 1) Failure mechanism of the frames is roughly classified into damage of the walls and breakage of the columns. If the columns of the frames were broken, bearing force of the frames is smaller. 2) If the columns of the frames were not broken, restoring force characteristics are varied by specification of the frames. 3) If the side of the columns in which was inserted the Sashigamoi was pulled, the columns are broken at about the half of the flexural strength.

Content from these authors
© 2015 Architectural Institute of Japan
Previous article Next article
feedback
Top