AIJ Journal of Technology and Design
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
Materials and Construction
RESEARCH ON THE DIAGNOSTIC ACCURACY OF THE TILE FINISH EXTERNAL WALL BY VARIOUS MEASURING METHODS
Miho MAKATAYAMAHiroyuki TANANOKaori NEMOTO
Author information
JOURNAL FREE ACCESS

2015 Volume 21 Issue 49 Pages 919-924

Details
Abstract

In this research, it experimented in exterior wall diagnosis using the trial examination object which created the exfoliation part of the outer wall artificially for the purpose of grasping the tendency about the detection accuracy and the measuring limit of the defective part for every diagnosis method. As a result, the thickness of the defective part and the size of the defect, it will vary depending investigation techniques such as an infrared inspection or a test hammer inspection by an inspector, there is a clear difference in the extent of degradation diagnosis can be revealed.

Content from these authors
© 2015 Architectural Institute of Japan
Previous article Next article
feedback