EVALUATION OF FLOOR RIGIDITY IN THE STRUCTURAL ANALYSIS IN THE CASE THAT FLOOR IS ATTACHED ONLY TO ONE SIDE OF BEAM
On the evaluation of floor rigidity in the structural analysis of reinforced concrete structure under horizontal loading (Part 2)
Kuniyasu SUZUKI
Author information
JOURNAL FREE ACCESS

2016 Volume 22 Issue 51 Pages 523-526

Details
Abstract

The purpose of this paper is to clarify the floor rigidity for the structural analysis in the case that the floor is attached only to one side of the beam. First, the ratio of the beam rigidity with floor for that without floor (the extra coefficient) was examined based on the results of finite element analysis of model composed of column, beam and floor. Next, the equation that estimated the extra coefficient was proposed based on the results of calculation in considering rigid zone proposed by authors in the end of members.

Content from these authors
© 2016 Architectural Institute of Japan