AIJ Journal of Technology and Design
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
Structures
THE CAPACITY VERIFICATION OF UNIT SYSTEM ARCHITECTURE WITH VERTICAL INTERLOCKING METHOD
Hisayuki HOSONOKoichi ARIMAMorihiro SHIBUTANIIori KANAOZheng YUYuko OGAWAMasayuki MATSUNAGATatsushi OTANIMakoto MURAMOTOKiyotaka MORISAKO
Author information
JOURNAL FREE ACCESS

2016 Volume 22 Issue 51 Pages 537-542

Details
Abstract

In this paper, new vertical interlocking method using high tension bolts is proposed for laying steel frame unit systems of container standard size. In this method, the location of tightening bolts is characteristic. The position is located inside of a beam from the column beam connection. Therefore the ultimate strength for the earthquake is decided by the plastic deformation of the beam without the fracture of the bolt. This performance is proved by full scale tests and numerical analyses.

Content from these authors
© 2016 Architectural Institute of Japan
Previous article Next article
feedback