EFFECTS OF SHAPE OF ROUGHENED CONCRETE BY CHIPPING ON SHEAR STRENGTH FOR EXISTING BUILDING
Takahide ABETakeshi HIWATASHIKeita SAKAMOTOYuya TAKASEKeiichi KATORI
Author information
JOURNAL FREE ACCESS

2018 Volume 24 Issue 57 Pages 655-660

Details
Abstract

In seismic retrofitting of existing building, concrete surface are chipped using an electric chipping hammer in order to connect retrofitting members to R/C frames. The roughened concrete surface has very complex concavo-convex shape. Therefore, estimating of the shear strength is very difficult.
In this paper, we conducted the shape-measurement and shape-analysis of roughened concrete. In addition, the shear tests are also conducted. Using the obtained data, we tried to evaluate the shear strength as sum of strength by bearing stress and by local interlocking. As a result, it was concluded that the optimal area ratio rcr was about 0.3.