A STUDY ON TESTING METHOD FOR MEASURING DRY DENSITY OF SHIELDING CONCRETE IN EXISTING STRUCTURES
Kazumasa INOUEMasashi TOKUNAGATakashi KITAGAWAKoji INODAToshiaki YAMADAMasazumi NAKAO
Author information
JOURNAL FREE ACCESS

2018 Volume 24 Issue 58 Pages 901-906

Details
Abstract

Using mold specimens according to JASS 5N T-601, and core specimens taken from the walls specimens, experiments investigating the effect some factors, such as the specimen size, water-binder ratio and cement type on the dry density were carried out. Then a testing method for the measuring dry density of shielding concrete was examined by using the core specimens. As a result, by using the core specimens taken from existing concrete structures, the authors could measure the dry density of shielding concrete based on the method of JASS 5N T-601.