AIJ Journal of Technology and Design
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
Materials and Construction
EVALUATION OF ROOT RESISTANCE AND DEGRADATION OF FRP WATERPROOFING MEMBRANES
Mitsuyuki KANZAKIShuuya TSUJIKiyokatsu HASEGAWA
Author information
JOURNAL FREE ACCESS

2019 Volume 25 Issue 61 Pages 1035-1038

Details
Abstract

Roofing materials suitable for roof greening have been studied, such as coating systems and sheet systems. When root resistance of the waterproof layer is not sufficient, plant roots breaks through the waterproof layer, which may lead to leakage. Especially directly on the waterproof layer, when planting laying soil. The purpose of this study is to clarify the roof resistance of FRP waterproof. In a way the same test method of JASS8T-401-2014, which was the bamboo plant, through the roots in the FRP waterproof was not confirmed. In JSTM G7101 method, the # 450 glass mat one or more thickness was confirmed to be at least 50 N.

Content from these authors
© 2019, Architectural Institute of Japan
Previous article Next article
feedback
Top