AIJ Journal of Technology and Design
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
Structures
EXPERIMENTAL STUDY ON SEISMIC PERFORMANCE OF WOODEN FRAME BEARING WALL APPLIED FOAMED PLASTIC INSULATION BOARD AND STRUCTURAL BOARD
Hideki HIRAKAWATakeyoshi UEMATSU
Author information
JOURNAL FREE ACCESS

2020 Volume 26 Issue 62 Pages 115-118

Details
Abstract

The external thermal insulation system for wooden houses is one of the popular thermal insulation systems in Hokkaido, Japan. We propose a bearing wall system for wooden frame houses to improve seismic and thermal insulation performance at the same work. The fastener to fix the external thermal insulation system is utilized also to fix structural board more tightly. And the foamed plastic board in the external thermal insulation system to improve thermal performance also improve seismic performance to keep clearance none between structural board and wooden frame. The system provides as almost three times of toughness as normal.

Content from these authors
© 2020, Architectural Institute of Japan
Previous article Next article
feedback