2022 Volume 28 Issue 68 Pages 121-126
This paper describes development of substructure real-time online response testing system (SROLT) for seismically isolated building with a small response delay using existing experimental equipment. Authors made analytical examinations of the influence of response delay to the test results caused by using existing experimental equipment, and developed a control method to minimize the problem. It was demonstrated by various test results that the developed system has sufficient accuracy as SROLT for seismically isolated buildings.
Ethical standards of the publisher (‘Ethical Standards Concerning the Peer Review for the Presentation of Architectural Transactions and Works’)