ANALYSIS OF THE ACTUAL STATUS OF THE BUILDING ENVELOPE STANDARD COMPLIANCE RATE AND ENVELOPE DESIGN SPECIFICATIONS FOR NON-RESIDENTIAL BUILDINGS
Masato MIYATA
Author information
JOURNAL FREE ACCESS

2022 Volume 28 Issue 70 Pages 1307-1312

Details
Abstract

This study analyzes the input and output data inputted into the calculation program for the Japanese building energy codes and clarifies the actual status of the building envelope standard compliance rate and envelope design specifications for non-residential buildings. This paper reveals the compliance rate of the envelope standard, the relationship between the building envelope performance index and the energy consumption performance index, and the average envelope design specifications by building type and region.