FUNDAMENTAL STUDY ON REDUCTION OF HEAT SHOCK RISK BY ROOM LAYOUT FOR HOUSE RENOVATION
Examination of air temperature of sanitary rooms by model analysis
Ayaka NISHINOIneko TANAKAKyoji YAMADAYoshihiko MATSUMOTOYasuhiro FUJIOKA
Author information
JOURNAL FREE ACCESS

2022 Volume 28 Issue 70 Pages 1325-1330

Details
Abstract

The purpose of this study is to reduce the risk of heat shock by changing floor plan at house renovation for the elderly. By numerical analysis using the actual renovation models and analysis of the layout of sanitary rooms including corridors, the items for changing floor plan to mitigate thermal environment were extracted. As a result of analyzing the renovation models applied those items, it was confirmed that the room temperature of sanitary rooms rise and the reduction of the heat shock risk by the proposed index.