AIJ Journal of Technology and Design
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
Structures
DEVELOPMENT OF REINFORCED CONCRETE MEMBERS WITH NON-CONTACT LAP SPLICED LONGITUDINAL BARS ENCASED IN CORRUGATED DUCTS
Hiroto TAKATSUHassane OUSALEM
Author information
JOURNAL FREE ACCESS

2023 Volume 29 Issue 71 Pages 150-155

Details
Abstract

Bending test of reinforced concrete beams using materials imported from Southeast Asia were tested to evaluate the non-contact lap splice length of longitudinal bars encased in grouted corrugated ducts. The test results showed that strengths and deformation capacities of the specimens with a lap splice length 20 times the bar diameter were almost the same as without lap splices. Then, a seismic test of a precast column with a lap splice length 30 times the bar diameter was carried out under varying axial loading. Test results revealed that the strength exceeded the calculated strength and the attained ductility was adequate.

Content from these authors
© 2023, Architectural Institute of Japan
Previous article Next article
feedback
Top