AIJ Journal of Technology and Design
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
Structures
EXPERIMENTAL STUDY ON ROOF SNOW CONTROL BY SNOW MELTING USING VENTILATION WASTE HEAT ON DOUBLE-LAYERED MEMBRANE ROOF WITH GENTLE SLOPE
Takahiro CHIBAHideharu YAMAGUCHITomohiro WATANABE
Author information
JOURNAL FREE ACCESS

2023 Volume 29 Issue 73 Pages 1221-1226

Details
Abstract

To establish the roof snow control by melting snow using ventilation waste heat on the double-layered membrane roof with gentle slope, the authors conducted the field experiment using the membrane roof prototype and examined the method for estimating the quantities of snow melting. As the results, the snow on the roof melted in case of the supply airflow temperature of approximately 20°C. In addition, the necessity to consider the thermal conductivity of the roof snow, and the setting value of snow density and the melting efficiency was clarified in the estimation of the snow melting quantities.

Content from these authors
© 2023, Architectural Institute of Japan
Previous article Next article
feedback
Top