FUNDAMENTAL CONSIDERATION FOR ESTABLISHING A SASH LIST USED FOR FIREPROOF WOODEN BUILDINGS
A study on the production system of large fireproof wooden buildings (Part 6)
Tadashi NISHIKAWAKouichi SATO
Author information
JOURNAL FREE ACCESS

2024 Volume 30 Issue 74 Pages 323-327

Details
Abstract

This paper aims to suggest a sash list used for fireproof wooden buildings. The followings are clarified; first, eight kinds of standard width for sliding sashes fit to the fireproof wooden construction technology. Second, the stud allocation of putting at 500 mm intervals is superior to the allocation at 455 mm. Third, the best thickness of covering the internal side of openings is 25 mm. Forth, only two means are needed to adjust the gap between a sash and opening. And last, three kinds of standard width fitting to the fireproof wooden construction technology comes from Kyusyu-Shikoku module.

Content from these authors
© 2024, Architectural Institute of Japan