Abstract

In this study, on site, the moisture conditions of concrete slab for targeting poured at different times were determined using humidity test paper and capacitive moisture meter until finishing floor covering. As a result, color chart value showed the same variation as that of temperature and humidity, indicating the possibility of being easily affected by the measurement environment. Moisture meter reading decreased with the lapse of lumber age, suggesting that it is not easily affected by the measurement environment.