CEILING RENOVATION BASED ON TIME-HISTORICAL ANALYSIS
Considering impact practical application of modified hertzdamp model
Yuichi KOITABASHIKenji TODAYukiko NAKATSUMasanao YANAGIHARA
Author information
JOURNAL FREE ACCESS

2025 Volume 31 Issue 77 Pages 157-162

Details
Abstract

To make a specific ceiling earthquake resistant, we isolate the ceiling and wall surfaces to ensure the original acoustic performance of the design, place anti-vibration rubber bearings at the collision points between the ceiling and wall and analyzed the collision phenomenon between the anti-vibration rubber and the wall. We modified the Hertzdamp model, which can appropriately evaluate the current state of collisions, and used a method applied to a structural analysis model that takes dissipated energy into account, to rationally set the design seismic intensity of the ceiling surface and apply it to the renovation of an actual project.

Content from these authors
© 2025, Architectural Institute of Japan
Previous article Next article