1998 Volume 4 Issue 6 Pages 89-94
The concept of the Municipal Kawasaki Hospital reconstruction is based in continuing medical treatment activity scale and, simultaneously carrying out improvement of functions and environment as well as shortening the construction schedule. The T-shape building was designed to overhang on top of the existing hospital. The cantilever part has 9 stories and 28.5m length which is 4/5 of the lower building part width. Wall foundations and permanent earth anchors are used to solve overturning moments due to Earthquake loading. A Megastructure system supports the overhanging part. And vertical vibration is controlled with oil dampers.
Ethical standards of the publisher (‘Ethical Standards Concerning the Peer Review for the Presentation of Architectural Transactions and Works’)