Analytical Sciences
Online ISSN : 1348-2246
Print ISSN : 0910-6340
ISSN-L : 0910-6340
Original Papers
Determination of Lead, Cadmium and Mercury in Microwave-digested Foodstuffs by RP-HPLC with an On-line Enrichment Technique
Zhangjie HUANGGuangyu YANGQiufen HUJiayuan YIN
Author information
JOURNAL FREE ACCESS

2003 Volume 19 Issue 2 Pages 255-258

Details
Abstract
A new method for the simultaneous determination of lead, cadmium and mercury ions in microwave-digested foodstuffs by reversed-phase high-performance liquid chromatography combined with on-line enrichment technique has been developed. The foodstuff samples were digested by microwave digestion. The lead, cadmium and mercury ions can be precolumn derivatized with 5,10,15,20-tetrakis(3-aminophenyl)porphine (T3APP) to form color chelates; then, the Hg-T3APP, Cd-T3APP and Pb-T3APP chelates can be enriched and separated on a valve switching HPLC system combined with on-line enrichment technique. The linearity ranges are 0.01 - 120 μg/l for each metal ion. The detection limits (S/N = 3) of lead, cadmium and mercury are 1.2 ng/l, 0.5 ng/l and 0.8 ng/l, respectively. This method was applied to the determination of lead, cadmium and mercury in foodstuffs with good results.
Content from these authors
© 2003 by The Japan Society for Analytical Chemistry
Previous article Next article