In the buffer solution of NH3-NH4Cl (pH = 8.5, 0.04 mo1 l-1), iron-Methylthymol Blue (MTB) can produce a sensitive polarographic wave at -1.10 V (vs. SCE) in the NaNO2. The peak current is linear with the concentration of the iron in the range of 3 × 10-8 - 5 × 10-6 mol l-1, and the detection limit is 1 × 10-8 mol l-1. By studying the characteristics of the wave and the electrode reaction mechanism, we can prove that the catalytic wave is an adsorption wave and that the peak current comes from the reduction of Fe(II). The molar ratio of iron to ligand was found to be 1:1. Adsorption particles are neutral molecules, the saturated adsorption quantity of the complex on the mercury electrode is 1.92 × 10-9 mol cm-2, according with the Frumkin isothermal formula. In the experiments, the adsorption coefficient (β) is 4.05 × 105; the adsorption factor (γ) is 0.70; the electron transfer number (n) is 2; the free energy (ΔGo) is 31.99 kJ mol-1; the transfer coefficient of the irreversible adsorption is 0.42 - 0.45; and the reaction velocity constant (Ks) is 1.35 s-1. This method, whose result is satisfying, can be applied to the detection of trace total iron contents in medicinal products.