Analytical Sciences
Online ISSN : 1348-2246
Print ISSN : 0910-6340
ISSN-L : 0910-6340
Original Papers
Simultaneous Kinetic Determination of Beryllium and Aluminium by Spectrophotometric H-Point Standard Addition Method
Abbas AFKHAMIAli Reza ZAREI
Author information
JOURNAL FREE ACCESS

2004 Volume 20 Issue 12 Pages 1711-1715

Details
Abstract
The H-point standard addition method (HPSAM), based on spectrophotometric measurements for simultaneous determination of beryllium and aluminium, is described. This method is based on the difference between their rates of reactions with Chrome Azurol S (CAS) in cetyltrimethylammonium bromide (CTAB) micellar media. The results showed that beryllium and aluminium could be determined simultaneously in the ranges of 10 - 200 and 10 - 300 ng mL-1, respectively. Under working conditions, the proposed method was successfully applied to the simultaneous determination of beryllium and aluminium in environmental, geochemical and alloy samples.