Analytical Sciences
Online ISSN : 1348-2246
Print ISSN : 0910-6340
ISSN-L : 0910-6340
Original Papers
Trace Elemental Analysis of Commercial Bottled Drinking Water by a Portable Total Reflection X-ray Fluorescence Spectrometer
Shinsuke KUNIMURAJun KAWAI
Author information
JOURNAL FREE ACCESS

2007 Volume 23 Issue 10 Pages 1185-1188

Details
Abstract
A portable total reflection X-ray fluorescence spectrometer was applied to commercial bottled drinking water containing 62 ppb (µg/L) V, 7.5 ppm (mg/L) Ca, and 1 ppm K. A dry residue, prepared by repeated pipetting and drying a 20 µL portion of drinking water on a sample holder six times, and another dry residue, prepared by pipetting and drying a 120 µL portion of the drinking water, were measured. The size of the dry residue of the drinking water was reduced by repeating the pipetting and drying. Calcium and potassium were easily detected in these two dry residues. Vanadium was detected in the dry residue prepared by repeated pipetting and drying. Vanadium, calcium, and potassium were quantified by using an internal standard, and the average quantified concentrations of V, Ca, and K were 91 ppb, 8.2 ppm, and 1.5 ppm, respectively. Although these quantified concentrations deviated from the certified concentrations (62 ppb of V, 7.5 ppm of Ca, and 1 ppm of K), it was possible for this portable spectrometer to estimate approximate concentrations.
Content from these authors
© 2007 by The Japan Society for Analytical Chemistry
Previous article Next article
feedback
Top