Analytical Sciences
Online ISSN : 1348-2246
Print ISSN : 0910-6340
ISSN-L : 0910-6340
Original Papers
Continuous Approach for Ultrasound-assisted Acid Extraction-Minicolumn Preconcentration of Chromium and Cobalt from Seafood Samples Prior to Flame Atomic Absorption Spectrometry
Maria C. YEBRA-BIURRUNSheila CANCELA-PÉREZ
Author information
JOURNAL FREE ACCESS

2007 Volume 23 Issue 8 Pages 993-996

Details
Abstract
A rapid and sensitive method has been proposed for the determination of chromium and cobalt in seafood samples by flame atomic absorption spectrometry combined with a dynamic ultrasound-assisted acid extraction and an on-line minicolumn preconcentration. The use of diluted nitric acid as extractant in a continuous mode at a flow rate of 3.5 mL min-1 and room temperature was sufficient for quantitative extraction of these trace metals from seafoods. A minicolumn containing a chelating resin was an excellent device for the quantitative preconcentration of chromium and cobalt prior to their detection. A flow-injection manifold was used as interface for coupling all analytical steps, which allowed the automation of the whole analytical process. A Plackett-Burman experimental design was used as a multivariate strategy for the optimization of both sample preparation and preconcentration steps. The method was successfully applied to the determination of chromium and cobalt in seafood samples.
Content from these authors
© 2007 by The Japan Society for Analytical Chemistry
Previous article Next article
feedback
Top