Analytical Sciences
Online ISSN : 1348-2246
Print ISSN : 0910-6340
ISSN-L : 0910-6340
Original Papers
Square Wave Voltammetry in the Determination of Ni2+ and Al3+ in Biological Sample
Alexandre T. PAULINOAlexandro M. M. VARGASLídia B. SANTOSJorge NOZAKIEdvani C. MUNIZElias B. TAMBOURGI
Author information
JOURNAL FREE ACCESS

2008 Volume 24 Issue 11 Pages 1443-1447

Details
Abstract

In this contribution, the amounts of Ni (nickel) and Al (aluminum) in tilapias (Oreochromis niloticus) were determined using square wave voltammetry (SWV) with glassy carbon working microelectrode with a mercury thin film, platinum counter electrode, and Ag/AgCl reference electrode. Ni was studied through the formation of the dimethylglyoxime-Ni (Ni-DMG) complex, while Al was studied through the formation of the Alizarin R-Al complex. The detection limit found for Ni-DMG and Alizarin R-Al complexes were 1.70 × 10-7 and 1.0 × 10-8 mol L-1, respectively. The voltammetric anodic curves for the Alizarin R-Al complex were recorded over the potential range from -0.8 to -0.05 V while the voltammetric cathodic curve for the Ni-DMG complex was recorded over the potential range from -0.7 to -1.2 V. These methods detected low concentrations of Ni and Al in biological samples efficiently.

Content from these authors
© 2008 by The Japan Society for Analytical Chemistry
Previous article Next article
feedback