Analytical Sciences
Online ISSN : 1348-2246
Print ISSN : 0910-6340
ISSN-L : 0910-6340
Determination of Trace Gallium by Electrothermal Atomic Absorption Spectrometry after Preconcentration on a Membrane Filter with a Finely Pulverized Anion-Exchange Resin
Junichi SHIDAShinichi MATSUZAKI
Author information
JOURNAL FREE ACCESS

1997 Volume 13 Issue 1 Pages 41-45

Details
Abstract

A sensitive method based on preconcentration on a membrane filter with a finely pulverized anion-exchange resin has been developed for the determination of gallium in water samples by electrothermal atomic absorption spectrometry. Gallium (10-60)ng, in 20-500ml of a sample solution, was retained as a Pyrocatechol Violet complex anion on a resin at pH 5; the resulting resin was filtered through a membrane filter. A portion of the resin with the membrane filter (3mm in diameter) was inserted into a cuvette, and the absorbance of gallium was measured at 294.4nm. The relative standard deviations for five measurements at 30ng of gallium was 5%. The detection limit was 1.5ng of gallium in 500ml (3ngGa l-1) of the water sample. The interference of various ions was studied, and the optimum conditions were developed for the determination of gallium in mine-drainage and river-water samples.

Content from these authors
© The Japan Society for Analytical Chemistry
Previous article Next article
feedback