Analytical Sciences
Online ISSN : 1348-2246
Print ISSN : 0910-6340
ISSN-L : 0910-6340
Preconcentration of Trace Metals with Dithiocarbamate-Chitin
Akiko HASEToshie KAWABATAKikuo TERADA
Author information
JOURNAL FREE ACCESS

1990 Volume 6 Issue 5 Pages 747-751

Details
Abstract
Dithiocarbamate-chitin (DTC-chitin) is synthesized by mixing chitin powder with carbon disulfide, 2-propanol and tetramethylammonium hydroxide in benzene. The DTC-chitin contains about 0.7% of sulfur, and the IR spectra of the DTC-chitin exhibit a small band at 1480cm-1 which is assigned to N-C=S. This polymer sorbs silver and copper from acidic solutions in the range of 1M (mol dm-3) nitric acid to pH 5.0, cadmium at pH 1.0-6.0, and cobalt and nickel at pH_??__2.5. On the other hand, untreated chitin sorbs these metal ions only at a pH above 7.0. The maximum flow rate for quantitative retention is 15ml min-1 for 0.04ppm of silver, cobalt and copper. The metals retained on the column are eluted with dilute nitric acid containing thiourea or hydrogen peroxide and are determined by flame atomic absorption spectrometry.
Content from these authors
© The Japan Society for Analytical Chemistry
Previous article Next article
feedback
Top