プラズマ応用科学
Online ISSN : 2435-1555
Print ISSN : 1340-3214
研究論文
マルチパスレーザー吸収分光法における膨張波管窓の感度向上への影響評価と時間分解気流診断
小林 隆士松井 信山田 和彦
著者情報
ジャーナル フリー

2021 年 29 巻 1 号 p. 15-21

詳細
抄録
Although expansion tubes have been used to simulate the atmospheric entry environment, the flow conditions have not been completely characterized. In our previous research, the sensitivity of laser absorption spectroscopy (LAS) was not high enough to diagnose ISAS/JAXA expansion tube flows. In this study, a multi-pass cell was formed to increase the sensitivity of LAS. Since the mirrors were set outside of the chamber, the window displacement by the shock arrival was found to decrease the sensitivity. From the ray trace calculation, the window angle should be less than 2.4 degree to keep the sensitivity enhancement of 44 times. As a result of multi-pass LAS diagnostics using the oxygen molecule line at 763.43 nm, it was found that the operation time of the expansion tube was 55 us, and the translation temperature was ranged from 4,400 K to 6,000 K.
著者関連情報
© 2021 プラズマ応用科学会
前の記事 次の記事
feedback
Top