Annals of Vascular Diseases
Online ISSN : 1881-6428
Print ISSN : 1881-641X
ISSN-L : 1881-641X
CASE REPORTS
Aorto–Esophageal Fistula Caused by Distal Stent Graft-Induced New Entry after Frozen Elephant Trunk Technique for Chronic Aortic Dissection
Yoshitaka Yamane Keijiro KatayamaShinya TakahashiTatsuya KurosakiTaijiro Sueda
Author information
JOURNAL OPEN ACCESS

2019 Volume 12 Issue 3 Pages 398-400

Details
Abstract

We present a case of aorto–esophageal fistula (AEF) caused by distal stent graft-induced new entry (dSINE) after the frozen elephant trunk (FET) technique for chronic aortic dissection. We propose that the combination of the spring-back force and the radial force of the FET may play a role in the occurrence of dSINE, leading to AEF. In this case, we successfully performed a three-stage surgery, including esophagectomy, descending aortic replacement, and esophageal reconstruction. To prevent this critical complication, additional endovascular aortic repair should be performed if the FET is not positioned at the straight portion of the descending aorta.

Content from these authors
© 2019 The Editorial Committee of Annals of Vascular Diseases. This article is distributed under the terms of the Creative Commons Attribution License, which permits use, distribution, and reproduction in any medium, provided the credit of the original work, a link to the license, and indication of any change are properly given, and the original work is not used for commercial purposes. Remixed or transformed contributions must be distributed under the same license as the original.

この記事はクリエイティブ・コモンズ [表示 - 非営利 - 継承 4.0 国際]ライセンスの下に提供されています。
https://creativecommons.org/licenses/by-nc-sa/4.0/deed.ja
Previous article Next article
feedback
Top