2014 年 19 巻 1 号 p. 1-9
We studied airborne concentrations of fungal spores and the thermal environment in houses with semi-basements surrounded by a natural forest. We examined the relationship between airborne fungi and the thermal environment, surrounding natural environment, structures of houses and use of a dehumidifier. The subject residential area was located in the northern part of Nara city, Nara prefecture, Japan. Six detached houses were included in this study. In residential areas, outdoor airborne concentrations were high during summer and autumn, correlated with humidity. The presence of Basidiomycetes was particularly notable, although the indoor concentration was lower than the outdoor level. In the semi-basement rooms, relative humidity was nearly always >80% when the residence was built; however, both the indoor humidity and fungal concentrations decreased greatly when a dehumidifier was used in this study. High levels of Aspergillus and Basidiomycetes were detected in semi-basements. Basidiomycetes are likely of outdoor origin, whereas Aspergillus might grow indoors. Moreover, the composition of fungal species differed according to room-structure and usage. Due to the health risks associated with high indoor concentrations of fungi, the utilization of the semi-basement or basement space requires adequate ventilation and dehumidification, beginning immediately after construction.