Comparison of Loop-Mediated Isothermal Amplification(LAMP) and Conventional Culture for the Detection of Legionella Species in Hot Spring Water Samples in Japan
KATSUNORI FURUHATATOSHIMITSU ANNAKAMASANARI IKEDOMASAHUMI FUKUYAMASHIN-ICHI YOSHIDA
Author information
JOURNAL FREE ACCESS

2005 Volume 10 Issue 3 Pages 117-120

Details
Abstract
We detected Legionella species in 125 samples of hot spring bath water from variousplaces in Japan using the culture and LAMP methods, and compared the results of the 2 methods. Legionella spp. was detected in 40 samples in the culture test, and 38 of these (95.0%) were also positive in the LAMP test, showing a high rate of consistency. Of the 85 negative samples in the culture test, 38 samples (44.7%) were positive in the LAMP test. The positive rate in the LAMP test was higher than that in the current culture test ; the test procedure wassimple, and judgments could be made in a few hours, showing that the LAMP method is useful for the rapid detection of Legionella spp.