Plasma Sterilization of Polyethylene Terephthalate Bottles by Pulsed Corona Discharge at Atmospheric Pressure
SATOSHI MASAOKA
著者情報
ジャーナル フリー

2007 年 12 巻 2 号 p. 59-63

詳細
抄録
A pulsed power supply was used to generate a corona discharge on a polyethyleneterephthalate bottle, to conduct plasma sterilization at atmospheric pressure. Before generating such a discharge, minute quantities of water were attached to the inner surface of the bottle and to the surface of a high voltage (HV) electrode inserted into the bottle. Next, highvoltage pulses of electricity were discharged between electrodes for 6.0s, while rotating the bottle. The resulting spore log reduction values of Bacillus subtilis and Aspergillus niger on the inner surface of the bottle were 5.5 and 6 or higher, respectively, and those on the HV electrode surface were each 6 or higher for both strains. The presence of the by-products gaseous ozone, hydrogen peroxide, and nitric ions resulting from the electrical discharge was confirmed.
著者関連情報
© The Society for Antibacterial and Antifungal Agents, Japan