1954 年 3 巻 9 号 p. 36-41
In previous year, a Wadsworth Littrow type infrared spectrometer using a galvanometer was built, In the spectrometer, a prism was set at minimum deviation, the prism and Wads-worth mirror were rotated simultaneously. In this time, a Littrow type spectrometer which is not a minimum deviation type has been built, and its resolution power has been examined theoretically and experimentally.