1994 Volume 43 Issue 1 Pages 67-69
In order to grasp the emission characteristics of automotive exhaust gas, high sensitivity and continuously measuring method is required. In this investigation, a continuous measuring technique for determining methanol in automotive exhaust gas with high resolution mass spectrometer was developed. Methanol in the automotive exhaust gas was measured every 1 second by a high resolution mass spectrometry at m/z=32.026. The exhaust gas was directly introduced to injected mass spectrometer. Detection limit of methanol with this method was 0.1 ppm (S/N=2), and 100% response time was 2 s.