Abstract
This study investigated the water flow through the vessels of tomato by using AE method. The detected frequency was compared with the calculated frequency by a bubble motion model considering attenuation characteristics of AE. The results suggest that the characteristics of frequency are similar to the analytical results. Considering the attenuation is effective for increasing the accuracy of moisture condition monitoring.