2017 Volume 71 Issue 1 Pages 379-385
In this study, in order to verify the usefulness of PMC spray painting to a prefabricated bar as a convenient corrosion-proofing method of a re-bar on the site the following experimental investigations were conducted. 1)adhesive strength and an antirust effect of PCM to a steel plate with PCM spray painted respectively by means of surface adhesive strength testing and salt spray testing, 2)bond strength of a re-bar with PCM spray painted to concrete by means of tension testing of a re-bar embedded in concrete and 3)flexural behavior of a RC beam using an assembling bar with PMC spray painted.