Cement Science and Concrete Technology
Online ISSN : 2187-3313
Print ISSN : 0916-3182
ISSN-L : 0916-3182
Environment and Recycling
DEVELOPMENT OF TECHNOLOGY FOR HIGH-ACCURACY TEMPERATURE MEASUREMENT OF CLINKER IN KILNS:PART1 ─ THEORY OF THE DUST-CANCELING METHOD AND APPLICATION TO AN EXISTING KILN
Mitsuhiro YAMAMOTOYoshiaki TAKATAHirokazu SHIMAYoshinori ITAYA
Author information
JOURNAL FREE ACCESS

2017 Volume 71 Issue 1 Pages 571-578

Details
Abstract

Precise temperature control during clinker burning is important for reducing energy consumption during cement production. Although radiation thermometers are conventionally used for measuring the clinker burning temperature, they suffer from the problem of poor measurement accuracy due to dust in the kiln. We therefore devised a method called the dust-canceling (DC) method for clinker temperature measurement that can eliminate the influence of dust in the kiln hood by using a radiation thermometer for measuring dust temperature in addition to the usual radiation thermometer for measuring clinker temperature. In this study, the validity of the DC method was confirmed with an experimental apparatus and applied to an existing production kiln. As a result, it was possible to obtain measured values closer to the theoretical clinker burning temperature compared with the conventional measurement method.