Cement Science and Concrete Technology
Online ISSN : 2187-3313
Print ISSN : 0916-3182
ISSN-L : 0916-3182
Environment and Recycling
DEVELOPMENT OF TECHNOLOGY FOR HIGH-ACCURACY TEMPERATURE MEASUREMENT OF CLINKER IN KILNS:PART2 ─ IMPROVEMENT OF MEASUREMENT ACCURACY FOR PRACTICAL APPLICATION
Mitsuhiro YAMAMOTOYoshiaki TAKATAHirokazu SHIMAYoshinori ITAYA
Author information
JOURNAL FREE ACCESS

2017 Volume 71 Issue 1 Pages 579-586

Details
Abstract

High-accuracy temperature control during clinker burning is important for reducing energy consumption in cement production. Although a radiation thermometer is conventionally used for temperature measurement of clinker, it suffers from the problem that the measurement accuracy is reduced by the influence of dust in the kiln. We therefore propose a measurement method that eliminates the influence of dust by using a separate radiation thermometer for measuring the dust temperature. However, this method suffers from the problem of measurement error when the dust concentration and temperature are non-uniform. To further improve measurement accuracy, we devised a method for measuring clinker temperature by using two radiation thermometers aimed at the clinker and a nose-ring plate attached to the outer circumference of the kiln exit. When this method was applied to an existing kiln, the measurement error was found to be -10 to 25℃, confirming that the accuracy was greatly improved over the conventional method.

Content from these authors
© Japan Cement Association
Previous article Next article
feedback
Top