Abstract
A new perfusion method for the dog kidney was introduced. In this method the left kidney of the recipient dog was perfused with the donor's blood using a pump-oxygenator system, while the renal nerve of the perfusion side was intact. Blood vessels of the perfused kidney showed good response to various vaso-active substances and to renal neave stimulation.