IEICE Communications Express
Online ISSN : 2187-0136
ISSN-L : 2187-0136
Assessment of measurement uncertainty for verification of compliance with guidelines for human exposure to EMFs from AM broadcasting transmitters
Byung Chan KimHyung-Do Choi
著者情報
ジャーナル フリー

2015 年 4 巻 9 号 p. 287-292

詳細
抄録
In this paper we analyze the uncertainty in measurement when assessing the exposure levels of the general public to RF electromagnetic fields (EMFs) from AM broadcasting transmitters. The purpose of measurement was to evaluate whether human exposure levels are in compliance (or not) with protection guidelines. Six sources of uncertainty were selected, and in order to allow for the propagation characteristics of the middle frequency range, the uncertainties of both the electric and magnetic fields were evaluated. Estimated uncertainties were identical to ±2.34 dB.
著者関連情報
© 2015 The Institute of Electronics, Information and Communication Engineers