Drug Discoveries & Therapeutics
Online ISSN : 1881-784X
Print ISSN : 1881-7831
ISSN-L : 1881-7831
Letter
Biotin treatment causing erroneous immunoassay results: A word of caution for clinicians
Raashda Ainuddin Sulaiman
Author information
JOURNAL FREE ACCESS

2016 Volume 10 Issue 6 Pages 338-339

Details
Abstract

Biotin or vitamin B7 when ingested in high doses may cause immunoassay interference leading to false potentially misleading results. It is important that clinicians should always interpret laboratory results in the context of patient's clinical state as erroneous results may lead to misdiagnosis and injudicious treatment with adverse patient outcome.

Content from these authors
© 2016 International Research and Cooperation Association for Bio & Socio-Sciences Advancement