Summaries of Technical Papers of Annual Meeting Japan Society for Finishings Technology
Online ISSN : 2760-3423
Summaries of Technical Papers of Annual Meeting 2017
Conference information

Summaries of Technical Papers of Annual Meeting 2017
A study on fire resistance of exterior tile finishing systems by using organic adhesive on lightweight cement mortar rendering.
Part.2 Evaluation of safety against the thermal shock in case of faling off of tile finishing layer.
*masaki UEMURAKazuhiro INAGAKIKenji MOTOHASHITomohiro NARUSEJun-ichi SUZUKITerusato INOUE
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Pages 137-140

Details
Abstract

Abrupt temperature change caused by tile peeling may cause harmful deformation and damage such as thermal shock represented by explosion of concrete, so it is targeted to light weight cement mortar outer wall using organic tile clad material, Experimental studies were conducted on the fireproof performance in the case where the tiles were peeled off and the fire protection coating was suddenly heated, assuming the condition heated from the outdoor side. It also confirmed the influence on light and heavy cement mortar outer wall tiled finish for fire protection performance as fire protection performance.

Content from these authors
© 2017 Japan Society for Finishings Technology

この記事はクリエイティブ・コモンズ [表示 - 非営利 - 改変禁止 4.0 国際]ライセンスの下に提供されています。