Fire Science and Technology
Online ISSN : 1882-0492
Print ISSN : 0285-9521
ISSN-L : 0285-9521
Experimental Study on Fire Resistance of Fire-Resistant Steel Beams
Y. SakumotoI. Nishida
著者情報
ジャーナル フリー

1998 年 18 巻 1 号 p. 1-9

詳細
抄録
This paper is to verify the fire resistance of beams made from fire-resistant(FR) structural steel by means of a full-scale loaded heat test. Because of the elements contained, FR Steel has higher strength than conventional structural steel at elevated temperatures. Its 0.2% proof stress at 600°C is equal to or greater than two-thirds the value specified at room temperature. Rockwool, ceramic fire protection, and foaming-type intumescent coating were used as fire-protection materials. The results showed that the fire-protection thickness can be reduced below what is required for conventional steel beams and that 1-h fire resistance can be obtained by intumescent coating with a lower insulation property.
著者関連情報
© 1998 Center for Fire Science and Technology, Research Institute for Science and Technology, Tokyo University of Science
次の記事
feedback
Top