グランド再生可能エネルギー国際会議論文集
Online ISSN : 2434-0871
Japan council for Renewable Energy(2018)
会議情報

BEHAVIOR OF FAILED PV MODULES UNDER DIFFERENT OPERATING TEMPERATURES
*Takumi Takashima
著者情報
会議録・要旨集 フリー

p. 30-

詳細
抄録

Measurements of failed PV modules under different operating temperature delineated the fact of output power reduction which becomes obvious only at high module temperature. Interconnect disconnection caused by cracks with module temperature dependence is one of the reason of the power reduction. Output power reduced modules under high operating temperature with disconnection of interconnect may pass the module performance warranty criteria at STC measurements. To evaluate the actual module performance correctly and fairly, not only the STC measurements for warranty criteria but also establishing the certified methods for on-site diagnosis of performance and the regulations for on-site inspections are required.

著者関連情報
© 2018 Japan Council for Renewable Energy (JCRE)
前の記事 次の記事
feedback
Top