日本地熱学会誌
Online ISSN : 1883-5775
Print ISSN : 0388-6735
ISSN-L : 0388-6735
論文
サーマルレスポンス試験の非充填型熱交換井への適用に関する 実験的検討
藤井 光小助川 洋幸ファラビ ハディジャリリ ナスラバディ サイード
著者情報
ジャーナル フリー

2016 年 38 巻 2 号 p. 43-51

詳細
抄録

The applicability of ungrouted ground heat exchangers (GHEs) in thermal response tests (TRTs) has not been confirmed since TRTs are generally carried out in grouted GHEs. In this work, two TRTs were carried out in a 102 m GHE of 100 mm casing ID under ungrouted and grouted conditions. The TRT results were interpreted through the conventional graphical method and more advanced approach using the cylindrical source function and optical fiber thermometers. The interpretation results of thermal conductivity in the ungrouted and grouted GHE showed reasonably good matching in both interpretation methods, indicating the applicability of the TRTs to ungrouted GHEs for the optimum design and the development of potential maps of ground source heat pump systems.

著者関連情報
© 2016 日本地熱学会
次の記事
feedback