日本地熱学会誌
Online ISSN : 1883-5775
Print ISSN : 0388-6735
ISSN-L : 0388-6735
地熱発電用ガス抽出装置の試験研究
相川 賢太郎田原 護
著者情報
ジャーナル フリー

1979 年 1 巻 2 号 p. 85-101

詳細
抄録
Geothermal steam contains a considerable amount of noncondensable gases. Consequently, the efficiency of the gas extracting system has a great influence on plant auxiliary power requirements and thereby the plant efficiency. We have developed and tested the new gas extraction system so called the E. R. R. system which consists of a steam ejector and a two stage radial blower. The steam ejector, having high efficiency at high vacuum pressures, and the radial blower, having high efficiency at low vacuum pressures, are combined to greatly increase overall efficiency. The steam ejectors in this system are driven by steam already used once in the turbine driving radial blower, so that steam consumption in this system decreases to about one hal f of that required for the system using only double-stage ejectors system. The characteristics of ejector driven by the low pressure steam were also analyzed in this test.
著者関連情報
© 日本地熱学会
前の記事 次の記事
feedback
Top