Journal of the Hydrogen Energy Systems Society of Japan
Online ISSN : 2436-5599
Print ISSN : 1341-6995
Determination of the pipeline diameter based on flow rate or calorific value to design a hydrogen pipeline network
Takeshi GaranMasayuki OosawaTomoaki TakeuchiKaori NumataShinobu Kawaguchi
Author information
RESEARCH REPORT / TECHNICAL REPORT FREE ACCESS

2012 Volume 37 Issue 2 Pages 138-144

Details
Abstract

In order to establish the design methodology of the hydrogen pipeline network, the design concept of the pipeline diameter was examined. Firstly, the flow experiments of hydrogen were conducted to verify the applicability of the general equation to calculate the relationship between flow rate and pressure loss in a pipe. By using the equation, the diameter of the hydrogen pipelines was determined under some virtual target conditions of flow rate or calorific value and was compared with that of typical city gas in Japan. As a result, it was suggested that the diameter of the hydrogen pipelines is equivalent to that of city gas in case of transporting the same calorific value

Content from these authors
© 2012 Hydrogen Energy Systems Society of Japan
Previous article Next article
feedback
Top