The Bulletin of National Institute of Technology, Hiroshima College
Online ISSN : 2434-494X
Print ISSN : 1883-9908
Study of the electronic device with lead-free solder mounted on ships
Toshifumi CHAENHiroshi OHYAMAMakoto FUJIIKenji YAMADAHikaru MISAKAHidehito MATSUBARAToshikazu IWAMOTO
Author information
RESEARCH REPORT / TECHNICAL REPORT OPEN ACCESS

2012 Volume 34 Pages 61-63

Details
Abstract

The toxic eff ects of lead are well known thus reducing lead in solders is important for the environment and the human health. Using the lead-free solders are being required to electronic devices on ships. NISHISHIBA ELECTRIC CO., LTD. and the members of Hiroshima-maru examined the Auto Voltage Regulator (AVR) with lead-free solder on Hiroshima-maru. The defects on the AVR caused from the shipʼs vibration and temperature were not found out in these examinations.

Content from these authors
© 2012 National Institute of Technology, Hiroshima College